    PVDF Capsule Filters - 12471

    For formulations where preservative binding or API adsorption compromises product potency, PVDF capsule filters minimize losses through ultra-low non-specific surface interactions. Engineered for demanding applications, the modified PVDF membrane surface minimizes adsorptive losses of proteins, preservatives, and active compounds, making the capsule format particularly suited to processing sensitive pharmaceutical and biological formulations. For this reason, the outcome is simplified regulatory documentation and reduced contamination risk, with each single-use capsule providing a validated, traceable filtration event.

    Key PVDF Membrane Characteristics

    • PVDF membrane capsules combine ultra-low protein binding with broad chemical compatibility, balancing sample recovery with resistance to the pharmaceutical solvents encountered in formulation processing.
    • PVDF capsule filters generate low extractable levels compatible with parenteral, ophthalmic, and other regulated dosage form applications.
    • PVDF capsule filters maintain consistent retention and flow performance across the operating pressure and temperature ranges encountered in standard pharmaceutical manufacturing conditions.
    • PVDF membrane construction within the capsule supports validated bacterial retention testing, with the sterilizing-grade performance documentation required by cGMP manufacturing protocols.
    • Hydrophilic PVDF membrane surfaces minimize non-specific adsorption of proteins, preservatives, and active pharmaceutical ingredients, protecting formulation potency through the filtration step.

    Key Capsule Construction Features

    • The sealed polypropylene housing is individually integrity-tested during manufacturing, verifying membrane installation and housing seal quality before the device leaves the production facility.
    • Polypropylene capsule housing supports autoclave sterilization at 121 degrees Celsius and withstands gamma irradiation exposure, accommodating both user-sterilized and factory-sterilized device configurations.
    • Thermally fused polypropylene construction eliminates adhesives, binders, and O-rings from the fluid path, reducing extractable contamination and simplifying material qualification.
    • Polypropylene capsule housing provides broad chemical compatibility from pH 1 to 14, resisting the acids, bases, and process chemicals that degrade alternative housing materials.

    As batch volumes and regulatory expectations continue to grow, your capsule filter selection becomes a process design decision that affects sterility assurance, product recovery, and operational cost per liter filtered. With these demands in mind, if your formulation contains preservatives, low-concentration APIs, or binding-sensitive biologics, the ultra-low adsorption characteristics of PVDF membrane construction preserve your product's potency through filtration. Elevate the quality of your analytical data today by standardizing on a filtration product built to meet the exact specifications of your applications.

    Sterilization Guidance

    Standard autoclave cycles at 121 degrees Celsius are compatible with the polypropylene housing and membrane assembly, allowing preparation for sterile applications at the point of use.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    46 psi
    Burst Pressure (psi)
    75 psi
    Capsule Format
    AcroPak 800
    Compliance Standards
    USP Class VI <88>; Endotoxin < 0.25 EU/mL (LAL)
    Construction
    Polypropylene
    Diameter
    22.5 cm
    Filling Bell (Yes/ No)
    No
    Filtration Area
    800 cm²
    Flow Rate
    0.9 L/min
    Inlet Connection
    1/4 to 1/2 in. stepped hose barb
    Material
    PVDF
    Max Batch Volume
    Large-volume batch processing
    Maximum Operating Pressure
    75 psi
    Maximum Operating Temperature (°C)
    40 °C
    Membrane Brand
    Fluorodyne II
    Outlet Connection
    1/4 to 1/2 in. stepped hose barb
    Pack Count
    1
    Pore Size (µm)
    0.2
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclave
    Vent (Yes/ No)
    Yes
    Wettability
    Hydrophilic
    • Drug Filtration - Ultra-low binding membrane filtration of pharmaceutical formulations where preservative and API recovery are critical.
    • Formulation Processing - Low-binding capsule filtration for pharmaceutical preparations where maintaining labeled potency is essential.
    • Protein Solutions - Capsule filtration of protein-containing solutions with ultra-low adsorptive losses across the fluid path.
    • Biological Products - Membrane processing of sera, biological extracts, and therapeutic proteins with minimal non-specific adsorption losses.
    • Preservative Sensitive - Filtration of formulations containing benzalkonium chloride and other preservatives susceptible to membrane binding.
    • Diagnostic Reagents - Filtration of sensitive diagnostic solutions where binding-related concentration changes affect assay performance.