Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 13 mm, 300/Pk - 2400
Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service and delivers sterilizing-grade gas and vent filtration. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane and sustains efficient flow on viscous samples. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- Absolute pore rating delivers reproducible retention across every protocol
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Insolubility in all known organic solvents avoids swelling and pore distortion
- Low extractables keep the chromatographic background clean
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
Housing Characteristics
- Medical-grade polypropylene with broad chemical compatibility
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Rigid polypropylene body maintains its geometry through routine filtration pressure
An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Connection Type
- Luer-Lock/ Minispike
- Construction
- Polypropylene (PP)
- Diameter
- 13mm
- Filtration Area
- 1.0cm²
- Flow Rate
- 112ml
- Holdup Volume
- < 14 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 60psi
- Pack Count
- 300
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.
- Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.