Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ wwPTFE Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ wwPTFE Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk Images

    Purchase Acro Disc Syringe Filters w/ wwPTFE Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk

    Acro Disc Syringe Filters w/ wwPTFE Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk
    Pall SKU: 2401

    $1,718.99
    Ships in 7 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 13 mm, 1000/Pk - 2401

    Whether the workflow is manual or automated, the housing platform behind every Pall syringe filter was validated to pair with the company's own proprietary membrane technology. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service while combining aqueous wetting with solvent resistance and suits solvent filtration where other membranes fail. The polypropylene housing preserves sample chemistry across the flow path and routes flow to minimize backpressure in service. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
    • Aqueous buffers and HPLC mobile phases wet the hydrophilic surface instantly
    • Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
    • High porosity minimizes hold-up volume for small sample volumes
    • Node-fibril microstructure resists compaction under sustained operating pressure

    Housing Characteristics

    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request a Certificate of Analysis for a specific Pall lot number from our support team.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    15psi (IPA)
    Connection Type
    Luer-Lock/ Minispike
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Holdup Volume
    < 30 µL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    100psi
    Pack Count
    1000
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
    • Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.