Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm, 200/Pk - 4219-N
Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE holds consistent absolute retention at the rated pore size while handling concentrated acids and strong bases and resists attack from the harshest process chemistries. The polypropylene housing preserves sample chemistry across the flow path and leaves no seam for sample to bypass the membrane. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Membrane Characteristics
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Insolubility in all known organic solvents avoids swelling and pore distortion
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Water contact angle near 120 degrees marks strong hydrophobicity
- Ionic and metallic extractable levels stay very low
Housing Characteristics
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Stable across the full aqueous pH range in routine sample work
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request current lead time on Pall filtration products from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 9psi (IPA)
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 2.8cm²
- Flow Rate
- 130ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 55°C
- Pack Count
- 200
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Ergonomic Filtration - Larger surface area reduces the hand force needed for manual filtration, helping minimize operator fatigue and strain.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.