Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm, 50/Pk - 4219TC
Decades spent on fluid management inform how Pall approaches laboratory-scale filtration challenges today. Syringe filters replace the separate holder and vacuum apparatus of bulk filtration with a single disposable unit, eliminating cleaning between samples. PTFE suits solvent and reagent filtration where other membranes fail while resisting attack from the harshest process chemistries and reaches the same absolute retention on every run. Polypropylene construction maintains a low-dead-volume internal flow path and presses snugly against the membrane during the pass. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.
Membrane Characteristics
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Low extractables keep the chromatographic background clean
- Water contact angle near 120 degrees marks strong hydrophobicity
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
Housing Characteristics
- Optimized internal geometry minimizes backpressure in service
- Thermal-bonded construction keeps adhesives out of the fluid path
- Resists stress cracking from aqueous salt and buffer solutions
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work so your downstream method starts with a clean sample. Request a Certificate of Analysis for a specific Pall lot number from our support team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 9psi (IPA)
- Connection Type
- Luer-Lock/ Luer Slip
- Diameter
- 25mm
- Filtration Area
- 2.8cm²
- Flow Rate
- 130ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 55°C
- Pack Count
- 50
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.