Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm, 200/Pk - 4225
Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. Hydrophobic PTFE blocks aqueous ingress in vent and gas applications while staying chemically inert against solvents, acids, and alkalis in service and provides bacterial retention in gas and vent streams. Polypropylene construction maintains a low-dead-volume internal flow path while preserving sample chemistry across the flow path and stays inert across common laboratory solvents. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- Minimal moisture absorption pairs with a low tare mass
- Water contact angle near 120 degrees marks strong hydrophobicity
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Node-fibril microstructure resists compaction under sustained operating pressure
- Absolute pore rating delivers reproducible retention across every protocol
Housing Characteristics
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- The seal formed against the membrane blocks bypass at rated operating pressure
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Reach the Tisch Scientific team for a quote or stock check on your Pall filtration setup.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 60ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 200
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.