Pall Acrodisc PTFE Syringe Filters, 1 µm, 25 mm, 200/Pk - 4226
Pall's proprietary membrane manufacturing capabilities put specialized media into the Acrodisc housing geometry. Syringe filters span a wide range of membrane chemistries and pore sizes, so the format can be matched to the sample matrix and solvent system in use. PTFE holds consistent absolute retention at the rated pore size and handles concentrated acids and bases. Polypropylene construction maintains a low-dead-volume internal flow path while pressing snugly against the membrane during the pass and sheds virtually no extractable material into the sample. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- Low extractables keep the chromatographic background clean
- Minimal moisture absorption pairs with a low tare mass
- Insolubility in all known organic solvents avoids swelling and pore distortion
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Stable across a wide operating temperature range for demanding methods
Housing Characteristics
- Thermal-bonded construction keeps adhesives out of the fluid path
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Housing rated for warm-sample filtration above standard laboratory temperature without softening or seal loss
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Talk to the Tisch Scientific team about consolidating your Pall filtration purchases under one volume-pricing agreement.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 200
- Pore Size (µm)
- 1
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.