Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 200/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 200/Pk Images

    Purchase Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 200/Pk

    Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 200/Pk
    Pall SKU: 4406

    $852.99
    Made to order. Contact us for lead time.
     

    Pall Acrodisc PVDF Syringe Filters, 0.2 µm, 25 mm, 200/Pk - 4406

    Decades spent on fluid management inform how Pall approaches laboratory-scale filtration challenges today. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. The surface modification reverses PVDF's natural affinity for protein adsorption while stopping bacteria at its finest sub-micron ratings and loads aqueous mobile phases on first contact. Low-extractable polypropylene keeps sample purity intact through the filtration pass while sustaining efficient flow on viscous samples and stays inert across common laboratory solvents. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Gamma irradiation sterilization causes no chain scission unlike polypropylene membranes
    • Aqueous and HPLC samples wet the surface without pre-wetting
    • Chemical compatibility spans the full pH 1 to 14 range
    • Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
    • Cast membrane structure releases no fibers, unlike depth-media prefilters

    Housing Characteristics

    • Housing rated for warm-sample filtration above standard laboratory temperature without softening or seal loss
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Stable across the full aqueous pH range in routine sample work
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    39psi
    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    50ml
    Holdup Volume
    < 100 µL
    Material
    Polyvinylidene Difluoride (PVDF)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    82°C
    Pack Count
    200
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Pharmaceutical QC - Supports routine quality control testing by reliably filtering mild organic solvent mixtures and drug formulations daily.
    • Biological Samples - Clarifies protein-rich solutions without loss of target molecules, preserving sample integrity for critical downstream assays.
    • Immunochemistry Research - Delivers exceptional chemical resistance for mild organic mixtures used in sensitive immunochemical research applications.
    • QuEChERS Extract Prep - Removes co-extracted waxes and pigments from QuEChERS extracts, protecting GC-MS and LC-MS systems during pesticide testing.
    • Microbiome Sampling - Concentrates waterborne microbial cells on a low-binding membrane ahead of DNA extraction and metagenomics sequencing.
    • Pre-Blot Sample Prep - Ensures ultra-low protein binding for maximum sample recovery ahead of sensitive immunodetection protocols and assays.