Acro Disc Syringe Filters w/ PTFE Membrane - 0.45um, 13mm, Male Slip Luer Outlet, 300/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ PTFE Membrane - 0.45um, 13mm, Male Slip Luer Outlet, 300/Pk Images

    Purchase Acro Disc Syringe Filters w/ PTFE Membrane - 0.45um, 13mm, Male Slip Luer Outlet, 300/Pk

    Acro Disc Syringe Filters w/ PTFE Membrane - 0.45um, 13mm, Male Slip Luer Outlet, 300/Pk
    Pall SKU: 4422

    $879.99
    Ships in 7 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 13 mm, 300/Pk - 4422

    Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. PTFE delivers absolute particle cutoff at the rated pore size and resists attack from the harshest process chemistries. The PP housing stays inert across common laboratory solvents and buffers in routine use while pressing snugly against the membrane during the pass and sustains efficient flow on viscous samples. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Membrane Characteristics

    • Minimal moisture absorption pairs with a low tare mass
    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Stable across a wide operating temperature range for demanding methods
    • Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration

    Housing Characteristics

    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion
    • Medical-grade polypropylene with broad chemical compatibility

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    9psi (IPA)
    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Flow Rate
    22ml
    Holdup Volume
    < 30 µL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    100°C
    Pack Count
    300
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
    • Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Ergonomic Filtration - Larger surface area reduces the hand force needed for manual filtration, helping minimize operator fatigue and strain.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.