    Pall Acrodisc PVDF Syringe Filters, 0.45 µm, 13 mm, 300/Pk - 4457

    Pall's proprietary membrane manufacturing capabilities put specialized media into the Acrodisc housing geometry. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. The hydrophilic PVDF membrane loads aqueous mobile phases on first contact and rejects particles above its absolute size threshold. Polypropylene construction maintains a low-dead-volume internal flow path while shedding virtually no extractable material into the sample and stands firm against aqueous acids, bases, and alcohols during regular handling. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Membrane Characteristics

    • Low extractables preserve a clean chromatographic baseline
    • Resistance to hydrolytic degradation exceeds that of nylon membranes
    • Fluoropolymer chemistry resists microbial and fungal degradation
    • Filtration preserves mammalian cell viability, phenotype, and growth
    • Thin membrane structure sustains high flow for fast sample throughput

    Housing Characteristics

    • Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion
    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Translucent housing wall allows visual confirmation of sample flow during filtration

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Reach the Tisch Scientific team for a quote or stock check on your Pall filtration setup.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    24psi
    Burst Pressure (psi)
    50psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Holdup Volume
    < 30 µL
    Material
    Polyvinylidene Difluoride (PVDF)
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    55°C
    Pack Count
    300
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Spectroscopy Prep - Provides optical clarity and low background interference, ideal for UV-Vis and fluorescence sample preparation work.
    • Pre-Blot Sample Prep - Ensures ultra-low protein binding for maximum sample recovery ahead of sensitive immunodetection protocols and assays.
    • Protein Purification - Facilitates routine clarification of chromatography samples, preventing column fouling without binding target proteins.
    • HPLC Prep - Delivers high flow rates for mild organic HPLC mobile phases, ensuring clean baselines and protecting analytical columns.
    • ELISA Biomarker Prep - Preserves low-abundance biomarkers during ELISA sample filtration, supporting accurate immunoassay quantitation.
    • IC Guard Filtration - Removes particulates from aqueous samples before ion analysis, keeping detector cells free of fouling between injections.