Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 13mm, 300/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 13mm, 300/Pk Images

    Purchase Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 13mm, 300/Pk

    Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 13mm, 300/Pk
    Pall SKU: 4485

    $991.99
    Ships in 7 weeks
     

    Pall Acrodisc Supor (PES) Syringe Filters, 0.45 µm, 13 mm, 300/Pk - 4485

    Pall validates the Supor membrane's retention at each stated pore rating, keeping biological sample clarification consistent from one production lot to the next. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. PES's low binding comes from surface chemistry, not the base polymer while keeping particle retention absolute at its specified micron rating and resists premature fouling under high-particulate sample loads. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane while sustaining efficient flow on viscous samples and stands firm against aqueous acids, bases, and alcohols during regular handling. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Membrane Characteristics

    • Pore structure integrity holds through autoclave cycles up to 126°C
    • Mechanical strength keeps the matrix intact under vacuum or pressure
    • The Supor membrane's graded structure keeps pressure drop low across a wide flow range
    • Chemical breadth spans alcohols, glycols, and aqueous buffers
    • Ionic extractables from the membrane stay very low

    Housing Characteristics

    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Stable across the full aqueous pH range in routine sample work

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Request a blanket-order quote to keep routine throughput volumes of Pall filters in stock.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    33psi
    Burst Pressure (psi)
    100psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Flow Rate
    55ml
    Holdup Volume
    < 30 µL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    55°C
    Pack Count
    300
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophilic
    • Robotic Tip Protection - Supor's low-particulate surface resists shedding, keeping narrow-bore robotic pipette tips clear of micro-clogs.
    • Life Science Prep - Speeds processing of viscous biological solutions, improving laboratory workflow efficiency during busy sample prep days.
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • Robotic Line Compatibility - Pall PES filters run cleanly through automated syringe platforms without snagging, jamming, or leaking mid-run.
    • Serum Filtration - Clarifies serum and plasma samples quickly while retaining critical proteins needed for accurate downstream analytical testing.