Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ PTFE Membrane - 1um, 25mm, 1000/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ PTFE Membrane - 1um, 25mm, 1000/Pk Images

    Purchase Acro Disc Syringe Filters w/ PTFE Membrane - 1um, 25mm, 1000/Pk

    Acro Disc Syringe Filters w/ PTFE Membrane - 1um, 25mm, 1000/Pk
    Pall SKU: 4503

    $2,452.99
    Ships in 7 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 1 µm, 25 mm, 1000/Pk - 4503

    Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. The PTFE matrix handles concentrated acids and bases across demanding methods while clarifying solvent streams at the rated pore size and withstands aggressive organics that degrade other media. Low-extractable polypropylene keeps sample purity intact through the filtration pass while routing flow to minimize backpressure in service and holds its seal true run after run. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Chemical resistance spans the full pH 1 to 14 range
    • Inert composition offers no nutrient source for microbial growth
    • Stable across a wide operating temperature range for demanding methods
    • Water contact angle near 120 degrees marks strong hydrophobicity

    Housing Characteristics

    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Optimized internal geometry minimizes backpressure in service

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Talk to the Tisch Scientific team about consolidating your Pall filtration purchases under one volume-pricing agreement.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Holdup Volume
    < 100 µL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    100°C
    Pack Count
    1000
    Pore Size (µm)
    1
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.