Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 1000/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 1000/Pk Images

    Purchase Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 1000/Pk

    Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 25mm, 1000/Pk
    Pall SKU: 4520

    $2,466.99
    Made to order. Contact us for lead time.
     

    Pall Acrodisc PVDF Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - 4520

    Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. PVDF provides sterilizing-grade retention at the rated sub-micron pore size while loading aqueous mobile phases on first contact and resists HPLC mobile phases, alcohols, and mild hydrocarbons. Polypropylene construction resists chemical degradation from routine sample matrices and maintains a low-dead-volume internal flow path. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.

    Membrane Characteristics

    • Autoclave sterilization cycles leave pore structure and flow performance intact
    • Gamma irradiation sterilization causes no chain scission unlike polypropylene membranes
    • Intrinsic protein binding runs lower than nylon or mixed cellulose ester
    • Fluorinated polymer chemistry resists ozone, UV, and ionizing radiation
    • Fluoropolymer chemistry resists microbial and fungal degradation

    Housing Characteristics

    • Optimized internal geometry minimizes backpressure in service
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation

    An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Upstream buffer clarification keeps your run from stalling on particulates that slipped through before they reach the column inlet or detector. Reach the Tisch Scientific team for a quote or stock check on your Pall filtration setup.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    39psi
    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    50ml
    Holdup Volume
    < 100 µL
    Material
    Polyvinylidene Difluoride (PVDF)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    82°C
    Pack Count
    1000
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Trace Analysis - Prevents non-specific binding in trace analysis, keeping low-concentration analytes in solution for reliable detection.
    • IC Guard Filtration - Removes particulates from aqueous samples before ion analysis, keeping detector cells free of fouling between injections.
    • Immunochemistry Research - Delivers exceptional chemical resistance for mild organic mixtures used in sensitive immunochemical research applications.
    • Protein Purification - Facilitates routine clarification of chromatography samples, preventing column fouling without binding target proteins.
    • Spectroscopy Prep - Provides optical clarity and low background interference, ideal for UV-Vis and fluorescence sample preparation work.
    • Biological Samples - Clarifies protein-rich solutions without loss of target molecules, preserving sample integrity for critical downstream assays.