Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk Images

    Purchase Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk

    Acro Disc Syringe Filters w/ PVDF Membrane - 0.2um, 13mm, Minispike Outlet, 1000/Pk
    Pall SKU: 4544

    $1,896.95
    Ships in 7 weeks
     

    Pall Acrodisc PVDF Syringe Filters, 0.2 µm, 13 mm, 1000/Pk - 4544

    Whether the workflow is manual or automated, the housing platform behind every Pall syringe filter was validated to pair with the company's own proprietary membrane technology. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. The surface modification reverses PVDF's natural affinity for protein adsorption while suiting HPLC sample preparation with immediate, reliable uptake and holds up to alcohols and mild hydrocarbon solvents. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while preserving sample chemistry across the flow path and holds its seal true run after run. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.

    Membrane Characteristics

    • Autoclave sterilization cycles leave pore structure and flow performance intact
    • Bacterial challenge testing with Brevundimonas diminuta at 10 million CFU per cm2 confirms sterilizing grade
    • Hydrochloric, dilute nitric, and up to 90% sulfuric acid cause no attack
    • Filtration preserves mammalian cell viability, phenotype, and growth
    • Limiting oxygen index runs high, supporting flame resistance and low smoke

    Housing Characteristics

    • Minispike inlet penetrates rubber vial septa to enable closed, contamination-free transfer from sealed source containers
    • Optimized internal geometry minimizes backpressure in service
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day from reagent and buffer preparation through routine sample clarification. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    39psi
    Burst Pressure (psi)
    50psi
    Connection Type
    Luer-Lock/ Minispike
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Holdup Volume
    < 30 µL
    Material
    Polyvinylidene Difluoride (PVDF)
    Maximum Operating Pressure
    100psi
    Maximum Operating Temperature (°C)
    55°C
    Pack Count
    1000
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Beverage QC - Clarifies wine, beer, and juice samples ahead of HPLC testing for organic acids, sugars, and preservatives.
    • Forensic Toxicology Screening - Clarifies urine samples ahead of LC-MS drug screening, supporting reliable detection of abused drugs and metabolites.
    • ELISA Biomarker Prep - Preserves low-abundance biomarkers during ELISA sample filtration, supporting accurate immunoassay quantitation.
    • Immunochemistry Research - Delivers exceptional chemical resistance for mild organic mixtures used in sensitive immunochemical research applications.
    • Biological Samples - Clarifies protein-rich solutions without loss of target molecules, preserving sample integrity for critical downstream assays.
    • Trace Analysis - Prevents non-specific binding in trace analysis, keeping low-concentration analytes in solution for reliable detection.