Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 13 mm, 300/Pk - 4553
Decades spent on fluid management inform how Pall approaches laboratory-scale filtration challenges today. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE holds consistent absolute retention at the rated pore size while withstanding aggressive organics that degrade other media and filters aggressive organic solvents without breakdown. Polypropylene construction resists chemical degradation from routine sample matrices while holding its seal true run after run and preserves sample chemistry across the flow path. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Membrane Characteristics
- Biological inertness resists enzymatic attack from proteases and lipases
- Node-fibril microstructure resists compaction under sustained operating pressure
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Minimal moisture absorption pairs with a low tare mass
- Chemical resistance spans the full pH 1 to 14 range
Housing Characteristics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Stable across the full aqueous pH range in routine sample work
- Standardized luer connection geometry provides secure engagement with standard syringe tips
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work so your downstream method starts with a clean sample. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 9psi (IPA)
- Burst Pressure (psi)
- 100psi
- Connection Type
- Luer-Lock/ Minispike
- Construction
- Polypropylene (PP)
- Diameter
- 13mm
- Filtration Area
- 1.0cm²
- Holdup Volume
- < 30 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 100psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 300
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.