Chat with us, powered by LiveChat

Secure Checkout
Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 25mm, 200/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 25mm, 200/Pk Images

    Purchase Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 25mm, 200/Pk

    Acro Disc Syringe Filters w/ Ion Chromatography (IC) Supor Membrane - 0.45um, 25mm, 200/Pk
    Pall SKU: 4585

    $901.95
    Ships in 7 weeks
     

    Pall Acrodisc Supor (PES) Syringe Filters, 0.45 µm, 25 mm, 200/Pk - 4585

    The Acrodisc housing's Supor membrane pairs an asymmetric pore gradient's flow rate benefit with ultra-low protein binding, both built into the same casting process. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. Supor sustains higher flow than standard PES at equal retention while resisting premature fouling under high-particulate sample loads and pairs fast flow with reduced protein adsorption. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane and routes flow to minimize backpressure in service. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.

    Membrane Characteristics

    • Pore structure integrity holds through autoclave cycles up to 126°C
    • Chemical breadth spans alcohols, glycols, and aqueous buffers
    • Antibody and protein samples pass through PES with minimal adsorptive loss
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
    • Supor's dirt-holding capacity runs higher than standard PES

    Housing Characteristics

    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Medical-grade polypropylene with broad chemical compatibility
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request volume pricing on Pall membranes for your recurring method needs.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    33psi
    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    300ml
    Holdup Volume
    < 100 µL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    100°C
    Pack Count
    200
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophilic
    • Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
    • Dissolution Testing - PES's naturally low binding profile keeps dissolution-testing throughput high without extra filtration force.
    • Robotic Line Compatibility - Pall PES filters run cleanly through automated syringe platforms without snagging, jamming, or leaking mid-run.
    • Serum Filtration - Clarifies serum and plasma samples quickly while retaining critical proteins needed for accurate downstream analytical testing.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Pharmaceutical Quality Control - Meets regulated lab standards where housing integrity and low extractable profiles are strictly required daily.