Acro Disc Syringe Filters w/ Supor Membrane, Sterile - 0.8um, 13mm, 75/Pk

Thumbnail Filmstrip of Acro Disc Syringe Filters w/ Supor Membrane, Sterile - 0.8um, 13mm, 75/Pk Images

    Purchase Acro Disc Syringe Filters w/ Supor Membrane, Sterile - 0.8um, 13mm, 75/Pk

    Acro Disc Syringe Filters w/ Supor Membrane, Sterile - 0.8um, 13mm, 75/Pk
    Pall SKU: 4608

    $223.95
    Made to order. Contact us for lead time.
     

    Pall Acrodisc Supor (PES) Syringe Filters, 0.8 µm, 13 mm, 75/Pk - 4608

    The Acrodisc housing's Supor membrane pairs an asymmetric pore gradient's flow rate benefit with ultra-low protein binding, both built into the same casting process. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. Supor's asymmetric membrane captures contaminants at the upstream surface while handling strong bases across a broad aqueous range and loads aqueous buffers with zero pre-wetting delay. Polypropylene housing is factory-sterilized and packaged to preserve that state until use and stays inert across common laboratory solvents. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Non-hydrogen-bonding surface avoids the polar adsorption nylon's amide backbone causes
    • Aromatic sulfone backbone underlies stability across the full pH range
    • High flow rate pairs with a low extractable background
    • Non-ionic surface avoids charge-driven protein binding of positively and negatively charged membrane types
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step

    Housing Characteristics

    • Stable across the full aqueous pH range in routine sample work
    • Polypropylene housing tolerates ethylene oxide gas sterilization cycles without softening or dimensional distortion
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Minimal extractable release from the housing supports sensitive analytical work downstream

    A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.

    Sterilization Guidance

    Factory sterilization supports immediate use in workflows where sterility assurance matters.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    13psi
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.0cm²
    Flow Rate
    150ml
    Holdup Volume
    < 60 µL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    55°C
    Pack Count
    75
    Pore Size (µm)
    0.8
    Sterility
    Sterile
    Wettability
    Hydrophilic
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Pharmaceutical Quality Control - Meets regulated lab standards where housing integrity and low extractable profiles are strictly required daily.
    • Robotic Tip Protection - Supor's low-particulate surface resists shedding, keeping narrow-bore robotic pipette tips clear of micro-clogs.
    • Serum Filtration - Clarifies serum and plasma samples quickly while retaining critical proteins needed for accurate downstream analytical testing.
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
    • PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.