Chat with us, powered by LiveChat

Secure Checkout
AcroPrep 384-Well Filter Plates, 100ul - 100K, Omega Membrane, Short Tips, Natural, 10/Pk

Thumbnail Filmstrip of AcroPrep 384-Well Filter Plates, 100ul - 100K, Omega Membrane, Short Tips, Natural, 10/Pk Images

    Purchase AcroPrep 384-Well Filter Plates, 100ul - 100K, Omega Membrane, Short Tips, Natural, 10/Pk

    AcroPrep 384-Well Filter Plates, 100ul - 100K, Omega Membrane, Short Tips, Natural, 10/Pk
    Pall SKU: 5080

    $889.95
    Ships in 6 weeks
     

    AcroPrep Polyethersulfone (PES) Filter Plate, 100 kDa MWCO, 10/Pk - 5080

    The multi-well plate processes many vessel samples in a single pass, removing particulates ahead of analytical injection and holding throughput steady. The PES membrane draws aqueous buffers through without pre-wetting and keeps protein adsorption low across the run. Uniform sample quality across every well supports the reproducibility that automated analytical methods depend on for reliable quantitation.

    Key Characteristics

    • Broad compatibility with aqueous buffers, aliphatic alcohols, glycols, and strong bases
    • Low protein binding preserves dilute analytes for maximum recovery
    • Naturally hydrophilic surface wets without pre-wetting in aqueous applications
    • Absolute pore size rating gives consistent results across protocols
    • Stable across the full pH 1 to 14 operating range

    Reproducible separations start with samples that reach the column free of particulates. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Reach out to the Tisch Scientific team for application support, volume pricing, and technical assistance with your filtration product selection.

    Capacity
    100uL
    Material
    Polyethersulfone (PES)
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.
    • Automated Dissolution Sampling - Filtered aliquots pulled from dissolution vessels arrive analysis-ready with no manual clarification step.
    • High-Throughput Cleanup - Plate-based clarification prepares large analytical batches in parallel and cuts hands-on preparation time per sample.
    • Pre-Chromatography Clarification - Clarified aliquots reach the autosampler free of particulates, protecting column lifetime across long runs.
    • Unattended Sampling Runs - Single-use plates paired with automated instruments enable clean, hands-off sample collection through a full test.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.