Chat with us, powered by LiveChat

Secure Checkout
AcroPrep Advance 96-Well Filter Plates for Aqueous Filtration - 350L, 0.2um Supor Membrane, 10/Pk

Thumbnail Filmstrip of AcroPrep Advance 96-Well Filter Plates for Aqueous Filtration - 350L, 0.2um Supor Membrane, 10/Pk Images

    Purchase AcroPrep Advance 96-Well Filter Plates for Aqueous Filtration - 350L, 0.2um Supor Membrane, 10/Pk

    AcroPrep Advance 96-Well Filter Plates for Aqueous Filtration - 350L, 0.2um Supor Membrane, 10/Pk
    Pall SKU: 8019

    $257.99
    Ships in 6 weeks
     

    AcroPrep Advance Polyethersulfone (PES) Filter Plate, 0.2 µm, 10/Pk - 8019

    High-throughput workflows collect and clarify samples in one plate-based step, cutting the handling variability that separate transfer steps introduce. PES accepts water-based reagents without surfactant preconditioning while staying stable across the pH 1 to 14 range and keeps protein adsorption low across the run. Consistent parallel clarification holds run-to-run reproducibility steady, so results stay comparable from well to well throughout the sequence.

    Key Characteristics

    • Absolute pore size rating gives consistent results across protocols
    • Stable across the full pH 1 to 14 operating range
    • High flow rate with low extractable background for clean preparations
    • Broad compatibility with aqueous buffers, aliphatic alcohols, glycols, and strong bases
    • Naturally hydrophilic surface wets without pre-wetting in aqueous applications

    Reproducible separations start with samples that reach the column free of particulates. Upstream sample clarification keeps your separations clean and reproducible from sample preparation through final injection. Contact Tisch Scientific for technical guidance on selecting the right filtration product for your specific application requirements.

    Capacity
    350uL
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • Pharmaceutical Release Testing - Clarified samples meet USP, EP, and JP method requirements for routine QC and batch release workflows.
    • Analytical Sample Prep - Turbid samples reduce to clean, injection-ready fractions for reproducible chromatographic and spectroscopic assays.
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.
    • Automated Dissolution Sampling - Filtered aliquots pulled from dissolution vessels arrive analysis-ready with no manual clarification step.
    • Pre-Chromatography Clarification - Clarified aliquots reach the autosampler free of particulates, protecting column lifetime across long runs.