Chat with us, powered by LiveChat

Secure Checkout
AcroPrep Advance 96-Well Filter Plates for Protein Purification - 350uL,0.45um Supor Membrane, 10/Pk

Thumbnail Filmstrip of AcroPrep Advance 96-Well Filter Plates for Protein Purification - 350uL,0.45um Supor Membrane, 10/Pk Images

    Purchase AcroPrep Advance 96-Well Filter Plates for Protein Purification - 350uL,0.45um Supor Membrane, 10/Pk

    AcroPrep Advance 96-Well Filter Plates for Protein Purification - 350uL,0.45um Supor Membrane, 10/Pk
    Pall SKU: 8029

    $257.99
    Ships in 6 weeks
     

    AcroPrep Advance Polyethersulfone (PES) Filter Plate, 0.45 µm, 10/Pk - 8029

    Parallel filtration across a full plate replaces the manual clarification step and keeps sample handling consistent from the first well to the last. PES minimizes protein binding to maximize sample and analyte recovery and draws aqueous samples through without pre-wetting. Consistent parallel clarification holds run-to-run reproducibility steady, so results stay comparable from well to well throughout the sequence.

    Key Characteristics

    • Broad compatibility with aqueous buffers, aliphatic alcohols, glycols, and strong bases
    • High flow rate with low extractable background for clean preparations
    • Absolute pore size rating gives consistent results across protocols
    • Stable across the full pH 1 to 14 operating range
    • Low protein binding preserves dilute analytes for maximum recovery

    Sample clarification before injection is the cheapest insurance your chromatography system has. Pre-injection filtration protects the resolution your methods depend on so your retention times and peak shapes stay consistent. Call on the Tisch Scientific team to standardize filtration products across your methods with volume pricing and documentation.

    Capacity
    350uL
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • Unattended Sampling Runs - Single-use plates paired with automated instruments enable clean, hands-off sample collection through a full test.
    • Automated Dissolution Sampling - Filtered aliquots pulled from dissolution vessels arrive analysis-ready with no manual clarification step.
    • Pre-Chromatography Clarification - Clarified aliquots reach the autosampler free of particulates, protecting column lifetime across long runs.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.
    • High-Throughput Cleanup - Plate-based clarification prepares large analytical batches in parallel and cuts hands-on preparation time per sample.
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.