AcroPrep Advance 96-Well Filter Plates for Lysate CLR - 350uL, 3.0um GFRP/0.2um Supor Membrane,10/Pk

Thumbnail Filmstrip of AcroPrep Advance 96-Well Filter Plates for Lysate CLR - 350uL, 3.0um GFRP/0.2um Supor Membrane,10/Pk Images

    Purchase AcroPrep Advance 96-Well Filter Plates for Lysate CLR - 350uL, 3.0um GFRP/0.2um Supor Membrane,10/Pk

    AcroPrep Advance 96-Well Filter Plates for Lysate CLR - 350uL, 3.0um GFRP/0.2um Supor Membrane,10/Pk
    Pall SKU: 8075

    $359.95
    Ships in 6 weeks
     

    AcroPrep Advance Glass Fiber / PES Filter Plate, 3 µm, 10/Pk - 8075

    Withdrawn media carries undissolved particulates into the analytical flow path, and the plate clears that load before injection to protect the instrument. PES handles strong bases and oils across a broad aqueous range while accepting water-based reagents without preconditioning and minimizes protein binding for high analyte recovery. Clarified aliquots keep particulate load off the analytical column and detector, extending instrument uptime across a full plate of samples.

    Key Characteristics

    • Naturally hydrophilic surface wets without pre-wetting in aqueous applications
    • Stable across the full pH 1 to 14 operating range
    • Low protein binding preserves dilute analytes for maximum recovery
    • High flow rate with low extractable background for clean preparations
    • Absolute pore size rating gives consistent results across protocols

    Reproducible separations start with samples that reach the column free of particulates. Pre-injection filtration protects the resolution your methods depend on by clearing particulates ahead of the column and frits. Send your application details to our technical service team and request a filtration product recommendation.

    Capacity
    350uL
    Pore Size (µm)
    3
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.
    • Unattended Sampling Runs - Single-use plates paired with automated instruments enable clean, hands-off sample collection through a full test.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.
    • Pharmaceutical Release Testing - Clarified samples meet USP, EP, and JP method requirements for routine QC and batch release workflows.
    • Automated Dissolution Sampling - Filtered aliquots pulled from dissolution vessels arrive analysis-ready with no manual clarification step.
    • High-Throughput Cleanup - Plate-based clarification prepares large analytical batches in parallel and cuts hands-on preparation time per sample.