    AcroPrep Advance PTFE Filter Plate, 0.2 µm, 5/Pk - 8686

    High-throughput workflows collect and clarify samples in one plate-based step, cutting the handling variability that separate transfer steps introduce. Chemically inert PTFE resists attack from the harshest process chemistries and suits solvent filtration where other membranes fail. Consistent parallel clarification holds run-to-run reproducibility steady, so results stay comparable from well to well throughout the sequence.

    Key Characteristics

    • Absolute pore size rating gives consistent results across protocols
    • Surface-treated for direct aqueous wetting without alcohol pre-wetting
    • Chemically inert against aggressive solvents, strong acids, and alkalis
    • Stable across a wide operating temperature range for demanding methods
    • Low extractables keep the chromatographic background clean

    Clarifying organic mobile phases before injection protects your chromatography while standing up to the solvent. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Reach out to the Tisch Scientific team for application support, volume pricing, and technical assistance with your filtration product selection.

    Capacity
    1mL
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • High-Throughput Cleanup - Plate-based clarification prepares large analytical batches in parallel and cuts hands-on preparation time per sample.
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.
    • Pre-Chromatography Clarification - Clarified aliquots reach the autosampler free of particulates, protecting column lifetime across long runs.
    • Pharmaceutical Release Testing - Clarified samples meet USP, EP, and JP method requirements for routine QC and batch release workflows.
    • Automated Dissolution Sampling - Filtered aliquots pulled from dissolution vessels arrive analysis-ready with no manual clarification step.