Chat with us, powered by LiveChat

Secure Checkout
AcroPrep 24-Well Filter Plate w/ Supor Membrane - 5um (2/Pkg)

Thumbnail Filmstrip of AcroPrep 24-Well Filter Plate w/ Supor Membrane - 5um (2/Pkg) Images

    Purchase AcroPrep 24-Well Filter Plate w/ Supor Membrane - 5um (2/Pkg)

    AcroPrep 24-Well Filter Plate w/ Supor Membrane - 5um (2/Pkg)
    Pall SKU: 97048

    $126.95
    Ships in 4 business days
     

    AcroPrep Polyethersulfone (PES) Filter Plate, 5 µm, 2/Pk - 97048

    Filter plates clarify withdrawn samples across a multi-well format, delivering analysis-ready aliquots in parallel throughout an automated sampling run. PES stays stable across the full pH 1 to 14 range while delivering sharp particle cutoff at the rated pore size and minimizes protein binding for high analyte recovery. Consistent parallel clarification holds run-to-run reproducibility steady, so results stay comparable from well to well throughout the sequence.

    Key Characteristics

    • Absolute pore size rating gives consistent results across protocols
    • Broad compatibility with aqueous buffers, aliphatic alcohols, glycols, and strong bases
    • Naturally hydrophilic surface wets without pre-wetting in aqueous applications
    • Low protein binding preserves dilute analytes for maximum recovery
    • Stable across the full pH 1 to 14 operating range

    Sample clarification before injection is the cheapest insurance your chromatography system has. Pre-injection filtration protects the resolution your methods depend on across your chromatography methods. Send your application details to our technical service team and request a filtration product recommendation.

    Capacity
    7mL
    Material
    Polyethersulfone (PES)
    Pore Size (µm)
    5
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • High-Throughput Cleanup - Plate-based clarification prepares large analytical batches in parallel and cuts hands-on preparation time per sample.
    • Pharmaceutical Release Testing - Clarified samples meet USP, EP, and JP method requirements for routine QC and batch release workflows.
    • Pre-Chromatography Clarification - Clarified aliquots reach the autosampler free of particulates, protecting column lifetime across long runs.
    • Parallel Sample Processing - Multiple vessel samples clarify at once, tightening run-to-run consistency across a full analytical sequence.
    • Column Protection - Particulate removal before injection guards analytical columns and detectors from fouling and stretches maintenance intervals.
    • Unattended Sampling Runs - Single-use plates paired with automated instruments enable clean, hands-off sample collection through a full test.