Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm - AP-4219TC
Decades spent on fluid management inform how Pall approaches laboratory-scale filtration challenges today. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. The PTFE matrix handles concentrated acids and bases across demanding methods while removing particles with absolute precision at each stated micron rating and suits gas, vent, and solvent-stream filtration. Polypropylene construction resists chemical degradation from routine sample matrices while sustaining efficient flow on viscous samples and holds its seal true run after run. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.
Membrane Characteristics
- Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
Housing Characteristics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Material
- Polytetrafluoroethylene (PTFE)
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Wettability
- Hydrophobic
- Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.