Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm, 200/Pk - AP-4225
Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. Each hydrophobic vent-rated filter carries manufacturer bacterial retention testing built into the design, letting a vent line stay in continuous service without repeating that testing on site between uses. Chemically inert PTFE achieves sterile-grade retention in gas and vent service while withstanding aggressive organics that degrade other media and suits solvent filtration where other membranes fail. Polyolefin construction sheds virtually no extractable material into the sample while pressing snugly against the membrane during the pass and stays inert across common laboratory solvents. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Membrane Characteristics
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Biological inertness resists enzymatic attack from proteases and lipases
- Low extractables keep the chromatographic background clean
- Water contact angle near 120 degrees marks strong hydrophobicity
Housing Characteristics
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- Standardized luer connection geometry provides secure engagement with standard syringe tips
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 60ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 200
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.