Chat with us, powered by LiveChat

Secure Checkout
Acro Disc PSF Syringe Filters w/ PTFE Membrane - 0.2um, 25mm, 50/Pk

Thumbnail Filmstrip of Acro Disc PSF Syringe Filters w/ PTFE Membrane - 0.2um, 25mm, 50/Pk Images

    Purchase Acro Disc PSF Syringe Filters w/ PTFE Membrane - 0.2um, 25mm, 50/Pk

    Acro Disc PSF Syringe Filters w/ PTFE Membrane - 0.2um, 25mm, 50/Pk
    Pall SKU: AP-4225TC

    $278.95 $348.00
    Save $69.05
    Ships in 6 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm - AP-4225TC

    Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. Gas and vent service calls for a hydrophobic syringe filter rated to the same sterilizing-grade pore size as its liquid counterpart. Hydrophobic PTFE blocks aqueous ingress in vent and gas applications while achieving sterile-grade retention in gas and vent service and withstands aggressive organics that degrade other media. The PP housing sustains efficient flow on viscous samples while pressing snugly against the membrane during the pass and stands firm against aqueous acids, bases, and alcohols during regular handling. Downstream equipment and work areas stay protected from airborne bacterial contamination once the vent path runs through the membrane.

    Membrane Characteristics

    • Node-fibril microstructure resists compaction under sustained operating pressure
    • Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
    • Validated against an aerosol Brevundimonas diminuta bacterial challenge
    • Inert composition offers no nutrient source for microbial growth
    • High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure

    Housing Characteristics

    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Translucent housing wall allows visual confirmation of sample flow during filtration
    • Stable across the full aqueous pH range in routine sample work
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Talk to the Tisch Scientific team about consolidating your Pall filtration purchases under one volume-pricing agreement.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Material
    Polytetrafluoroethylene (PTFE)
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Wettability
    Hydrophobic
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
    • Cryogenic Fluids - Delivers consistent performance across extreme temperature ranges, filtering cryogenic liquids with dependable, reliable results.
    • Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
    • Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.