    Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm, 200/Pk - AP-4303

    The Acrodisc housing platform pairs with Pall's own proprietary membrane media, built for demanding analytical and bioprocess workflows. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. PTFE suits solvent and reagent filtration where other membranes fail while suiting gas, vent, and solvent-stream filtration and reaches the same absolute retention on every run. Polyolefin construction sheds virtually no extractable material into the sample while holding its seal true run after run and stands firm against aqueous acids, bases, and alcohols during regular handling. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Prefiltration

    • Added glass fiber stage extends usable throughput by delaying membrane clogging
    • Depth-loading glass fiber matrix captures particulate throughout its full thickness
    • Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
    • Two-stage construction pairs a borosilicate glass fiber prefilter with the downstream membrane

    Membrane Characteristics

    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Biological inertness resists enzymatic attack from proteases and lipases
    • Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
    • Non-fibrous, fully synthetic structure sheds no fibers into filtrate
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack

    Housing Characteristics

    • Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • The seal formed against the membrane blocks bypass at rated operating pressure

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    9psi (IPA)
    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    130ml
    Holdup Volume
    < 100 µL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    100°C
    Pack Count
    200
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
    • Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
    • Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Ergonomic Filtration - Larger surface area reduces the hand force needed for manual filtration, helping minimize operator fatigue and strain.
    • Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.