Acro Disc PSF Syringe Filters w/ PTFE Membrane - GxF/0.45um, 25mm, 50/pk

Thumbnail Filmstrip of Acro Disc PSF Syringe Filters w/ PTFE Membrane - GxF/0.45um, 25mm, 50/pk Images

    Purchase Acro Disc PSF Syringe Filters w/ PTFE Membrane - GxF/0.45um, 25mm, 50/pk

    Acro Disc PSF Syringe Filters w/ PTFE Membrane - GxF/0.45um, 25mm, 50/pk
    Pall SKU: AP-4303TC

    $278.95 $348.00
    Save $69.05
    Ships in 6 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm - AP-4303TC

    Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The PTFE matrix handles concentrated acids and bases across demanding methods while clarifying solvent streams at the rated pore size and suits gas, vent, and solvent-stream filtration. Polypropylene construction maintains a low-dead-volume internal flow path while preserving sample chemistry across the flow path and stays inert across common laboratory solvents. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Prefiltration

    • Added glass fiber stage extends usable throughput by delaying membrane clogging
    • Glass fiber prefilter stage sustains flow through particle-laden, hard-to-filter samples
    • Two-stage construction pairs a borosilicate glass fiber prefilter with the downstream membrane
    • Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples

    Membrane Characteristics

    • Biological inertness resists enzymatic attack from proteases and lipases
    • Membrane integrity holds across repeated autoclave sterilization cycles at 121°C to 134°C
    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Water contact angle near 120 degrees marks strong hydrophobicity
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack

    Housing Characteristics

    • Resists stress cracking from aqueous salt and buffer solutions
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Thermal-bonded construction keeps adhesives out of the fluid path

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Reach out to the Tisch Scientific team about minimum order quantities and shipping timelines for your filtration product selection.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Material
    Polytetrafluoroethylene (PTFE)
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Wettability
    Hydrophobic
    • Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.
    • Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
    • Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.