Pall Acrodisc Nylon Syringe Filters, 0.45 µm, 25 mm, 50/Pk - AP-4438TC
Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Nylon arrives in economical bulk packaging for high-volume routine filtration while delivering sharp particle cutoff at the rated pore size and resists alkaline buffer systems. The PP housing sustains efficient flow on viscous samples while holding its seal true run after run and resists degradation from routine sample matrices. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.
Membrane Characteristics
- Synthetic polyamide backbone resists microbial and enzymatic degradation unlike cellulose membranes
- Compatible with most HPLC mobile phases for sample clarification
- Solvent compatibility extends to both acetonitrile and methanol
- Saturation moisture uptake reaches up to 8% by resin weight
- Resonance-stabilized amide bonds anchor nylon's resistance to alkaline hydrolysis
Housing Characteristics
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 29psi
- Connection Type
- Luer-Lock/ Luer Slip
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 215ml
- Holdup Volume
- < 125 µL
- Material
- Nylon
- Maximum Operating Pressure
- 60psi
- Maximum Operating Temperature (°C)
- 82°C
- Pack Count
- 50
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Non-autoclavable
- Wettability
- Hydrophilic
- Cannabis Potency Testing - Clarifies cannabinoid extracts in ethanol or hydrocarbon solvents ahead of HPLC potency and pesticide-residue analysis.
- Automated Sample Prep - Withstands the rigors of robotic syringe filtration systems without jamming or leaking to ensure uninterrupted runs.
- QuEChERS Cleanup - Clarifies acetonitrile food extracts after dispersive cleanup, protecting GC-MS and LC-MS systems during pesticide screening.
- Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.
- HPLC Sample Prep - Clarifies mixed aqueous and organic solvents to ensure stable baselines and protect chromatography columns from clogging.
- Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.