Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm, 1000/Pk - AP-4501
The Acrodisc housing platform pairs with Pall's own proprietary membrane media, built for demanding analytical and bioprocess workflows. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE holds consistent absolute retention at the rated pore size while suiting solvent filtration where other membranes fail and suits gas, vent, and solvent-stream filtration. The polypropylene housing routes flow to minimize backpressure in service while leaving no seam for sample to bypass the membrane and stands firm against aqueous acids, bases, and alcohols during regular handling. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.
Membrane Characteristics
- Ionic and metallic extractable levels stay very low
- High porosity minimizes hold-up volume for small sample volumes
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Low non-specific protein binding preserves recovery of biomolecules and therapeutic proteins during filtration
- Minimal moisture absorption pairs with a low tare mass
Housing Characteristics
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Medical-grade polypropylene with broad chemical compatibility
- The seal formed against the membrane blocks bypass at rated operating pressure
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 9psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 130ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Aggressive Solvents - Clarifies chlorinated hydrocarbons and aromatics without membrane degradation, delivering pure filtrate quality consistently.
- Toxicology Screening - Clarifies protein-precipitated serum, plasma, and urine extracts ahead of LC-MS or GC-MS drug screening analysis.
- Pump Protection - Acts as a hydrophobic barrier that protects vacuum pumps from corrosive moisture and particulate damage.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.
- Air Monitoring - Ensures precise capture of airborne particulates for environmental analysis in demanding atmospheric monitoring conditions.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.