    Acro Disc PSF Syringe Filters w/ PTFE Membrane - 0.45um, 25mm Autopack Tubes (25/Pkg 200/cs)
    Pall SKU: AP-4518

    $785.95
    Ships in 6 weeks
     

    Pall Acrodisc PTFE Syringe Filters, 0.45 µm, 25 mm, 25/Pk - AP-4518

    Every Pall production lot passes through the same arc, raw membrane casting to a finished device's integrity test, before performance counts as consistent. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. PTFE suits solvent and reagent filtration where other membranes fail while suiting gas, vent, and solvent-stream filtration and stays chemically inert against solvents, acids, and alkalis. The polypropylene housing holds its seal true run after run and maintains a low-dead-volume internal flow path. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • UL 94 V-0 rating confirms the highest self-extinguishing classification
    • Chemical resistance spans the full pH 1 to 14 range
    • Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
    • Strong oxidizing agents like nascent chlorine and concentrated sodium hydroxide cause no attack
    • Absolute pore rating delivers reproducible retention across every protocol

    Housing Characteristics

    • Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Maintains dimensional form and seal integrity through elevated-temperature sample preparation at its rated limit

    An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Request Pall's validation documentation from the Tisch Scientific team ahead of a method transfer or audit.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    9psi (IPA)
    Burst Pressure (psi)
    60psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    510ml
    Holdup Volume
    < 100 µL
    Material
    Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    100°C
    Pack Count
    25
    Pore Size (µm)
    0.45
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophobic
    • Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
    • Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
    • Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
    • Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
    • Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
    • Photoresist Filtration - Clarifies photoresist solutions in organic casting solvent ahead of spin-coating, reducing particulate defect risk.