Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - AP-4521
Pall's proprietary membrane manufacturing capabilities put specialized media into the Acrodisc housing geometry. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. Hydrophobic PTFE blocks aqueous ingress in vent and gas applications while providing bacterial retention in gas and vent streams and resists attack from the harshest process chemistries. Thermal-bonded PP construction leaves no seam for sample to bypass the membrane and sheds virtually no extractable material into the sample. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Membrane Characteristics
- Low extractables keep the chromatographic background clean
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Surface energy near 18.5 dynes per centimeter repels oils and nonpolar liquids
- Validated against an aerosol Brevundimonas diminuta bacterial challenge
- Absolute pore rating delivers reproducible retention across every protocol
Housing Characteristics
- Thermal-bonded construction keeps adhesives out of the fluid path
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Housing rated for warm-sample filtration above standard laboratory temperature without softening or seal loss
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request current lead time on Pall filtration products from the Tisch Scientific team.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 60ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
- Fuel Analysis Prep - Clarifies gasoline and other petroleum samples ahead of gas chromatography, protecting injector ports from residue buildup.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.