Pall Acrodisc Supor (PES) Syringe Filters, 0.45 µm, 25 mm, 1000/Pk - AP-4785
Pall validates the Supor membrane's retention at each stated pore rating, keeping biological sample clarification consistent from one production lot to the next. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. PES's low binding comes from surface chemistry, not the base polymer and clears particulate matter above its coarse cutoff threshold. The polypropylene housing preserves sample chemistry across the flow path while pressing snugly against the membrane during the pass and sustains efficient flow on viscous samples. When chromatographic methods demand particle-free injections, the column stays clean from run to run, protecting method performance and column life.
Membrane Characteristics
- Supor binds far less protein than standard PES
- High flow rate pairs with a low extractable background
- Absolute pore size rating holds consistent across every lot
- Sulfone backbone's hydrolytic stability tolerates repeated autoclave steam sterilization cycles
- Mechanical strength keeps the matrix intact under vacuum or pressure
Housing Characteristics
- Low moisture absorption keeps the housing dimensionally stable through humid storage and shipping
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Housing rated for warm-sample filtration above standard laboratory temperature without softening or seal loss
- The seal formed against the membrane blocks bypass at rated operating pressure
Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 33psi
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 300ml
- Holdup Volume
- < 100 µL
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.45
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophilic
- Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
- UHPLC/HPLC Prep - Delivers low extractables to ensure noise-free baselines in sensitive chromatography applications and trace analysis.
- Serum Filtration - Clarifies serum and plasma samples quickly while retaining critical proteins needed for accurate downstream analytical testing.
- Robotic Tip Protection - Supor's low-particulate surface resists shedding, keeping narrow-bore robotic pipette tips clear of micro-clogs.
- PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.
- Dissolution Testing - PES's naturally low binding profile keeps dissolution-testing throughput high without extra filtration force.