Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm, 200/Pk - AP-4790
Whether the workflow is manual or automated, the housing platform behind every Pall syringe filter was validated to pair with the company's own proprietary membrane technology. A single-use hydrophobic vent filter reaches sterilizing-grade retention on a vent line without the autoclave cycle or in-line housing a reusable gas filtration setup would require. PTFE filters aggressive organic solvents without swelling or breakdown and provides bacterial retention in gas and vent streams. The polypropylene housing routes flow to minimize backpressure in service and stands firm against aqueous acids, bases, and alcohols during regular handling. A vent or gas line stays free of airborne bacteria once a hydrophobic, sterilizing-grade membrane is in the path.
Prefiltration
- Depth-loading glass fiber matrix captures particulate throughout its full thickness
- High dirt-holding capacity suits very turbid, high-solids sample loads
- Added glass fiber stage extends usable throughput by delaying membrane clogging
- Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
Membrane Characteristics
- Water contact angle near 120 degrees marks strong hydrophobicity
- Gas-venting and liquid-blocking function survives repeated autoclave sterilization cycles
- Absolute pore rating delivers reproducible retention across every protocol
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Minimal moisture absorption pairs with a low tare mass
Housing Characteristics
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Housing rated for warm-sample filtration above standard laboratory temperature without softening or seal loss
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Rigid polypropylene body maintains its geometry through routine filtration pressure
An aggressive solvent can leach or break down a vulnerable filter and carry debris into your prep. Solvent-stream filtration handles the solvents and reagents your methods rely on from initial prep through final use. Reach the Tisch Scientific team for a quote or stock check on your Pall filtration setup.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 60ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 200
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Automated Sample Prep - PTFE's chemical inertness holds up through repeated robotic filtration cycles without degrading or swelling over time.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Agrochemical Formulation QC - Clarifies technical pesticide concentrates in organic solvent ahead of HPLC potency and impurity analysis.
- Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Mobile Phase Prep - Extends column life by consistently removing particulates from organic HPLC mobile phases before every injection.