Pall Acrodisc PTFE Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - AP-4791
The Acrodisc housing platform pairs with Pall's own proprietary membrane media, built for demanding analytical and bioprocess workflows. A syringe filter with a hydrophobic vent-rated membrane keeps gas and vent lines free of microbial ingress. The hydrophobic PTFE membrane provides bacterial retention in gas and vent streams and suits solvent filtration where other membranes fail. Low-extractable polypropylene keeps sample purity intact through the filtration pass while staying inert across common laboratory solvents and presses snugly against the membrane during the pass. No separate sterilization cycle is needed when the gas path already runs through a validated sterile-grade membrane.
Prefiltration
- Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
- Depth-loading glass fiber matrix captures particulate throughout its full thickness
- Glass fiber prefilter stage sustains flow through particle-laden, hard-to-filter samples
- Added glass fiber stage extends usable throughput by delaying membrane clogging
Membrane Characteristics
- Inert composition offers no nutrient source for microbial growth
- Validated against an aerosol Brevundimonas diminuta bacterial challenge
- UL 94 V-0 rating confirms the highest self-extinguishing classification
- Non-fibrous, fully synthetic structure sheds no fibers into filtrate
- Non-wetting pore surface blocks liquid water while passing water vapor freely
Housing Characteristics
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Maintains dimensional form and seal integrity through elevated-temperature sample preparation at its rated limit
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request a quote on bulk pricing for larger filtration orders from the Tisch Scientific team.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 15psi (IPA)
- Burst Pressure (psi)
- 60psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 3.9cm²
- Flow Rate
- 60ml
- Holdup Volume
- < 100 µL
- Material
- Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 100°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophobic
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Dissolution Testing - Stops the dissolution reaction and clarifies samples, with low API binding for accurate potency quantitation.
- Trace Metals Analysis - PTFE's low metal-extractable profile clarifies acid-digested samples for clean, low-background ICP-MS and ICP-OES results.
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Sample Protection - Low-binding properties ensure maximum recovery of low-concentration analytes, improving accuracy in quantitative assay results.