Acro Disc PSF Syringe Filters w/ Supor Membrane - GxF/0.2um, 25mm, 200/Pk

Thumbnail Filmstrip of Acro Disc PSF Syringe Filters w/ Supor Membrane - GxF/0.2um, 25mm, 200/Pk Images

    Purchase Acro Disc PSF Syringe Filters w/ Supor Membrane - GxF/0.2um, 25mm, 200/Pk

    Acro Disc PSF Syringe Filters w/ Supor Membrane - GxF/0.2um, 25mm, 200/Pk
    Pall SKU: AP-4799

    $890.95
    Ships in 7 weeks
     

    Pall Acrodisc Supor (PES) Syringe Filters, 0.2 µm, 25 mm, 200/Pk - AP-4799

    Pall validates the Supor membrane's retention at each stated pore rating, keeping biological sample clarification consistent from one production lot to the next. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. The PES matrix tolerates aliphatic alcohols, glycols, and aqueous buffers and needs a surface treatment before its polysulfone base wets. The polypropylene housing preserves sample chemistry across the flow path while standing firm against aqueous acids, bases, and alcohols during regular handling and maintains a low-dead-volume internal flow path. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Prefiltration

    • Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
    • Depth-loading glass fiber matrix captures particulate throughout its full thickness
    • Two-stage construction pairs a borosilicate glass fiber prefilter with the downstream membrane
    • High dirt-holding capacity suits very turbid, high-solids sample loads

    Membrane Characteristics

    • Sterilizing-grade PES membrane lots are challenge-tested against Brevundimonas diminuta to qualify 0.2 micron retention
    • Absolute pore size rating holds consistent across every lot
    • Ionic extractables from the membrane stay very low
    • Non-ionic surface avoids charge-driven protein binding of positively and negatively charged membrane types
    • Compatibility spans both nucleic acid and protein-based filtration

    Housing Characteristics

    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
    • Optimized internal geometry minimizes backpressure in service

    A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Pre-injection filtration protects the resolution your methods depend on across your chromatography methods. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    51psi
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lock/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    25mm
    Filtration Area
    3.9cm²
    Flow Rate
    175ml
    Holdup Volume
    < 100 µL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    55°C
    Pack Count
    200
    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Sterilization
    Autoclavable at 121°C for 15-20 min
    Wettability
    Hydrophilic
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
    • Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
    • UHPLC/HPLC Prep - Delivers low extractables to ensure noise-free baselines in sensitive chromatography applications and trace analysis.
    • Pharmaceutical Quality Control - Meets regulated lab standards where housing integrity and low extractable profiles are strictly required daily.
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.