Pall Acrodisc Water-Wettable PTFE Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - AP-4915
Syringe filter production at Pall answers to the same quality infrastructure standing behind its process-scale filtration systems. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. The hydrophilic PTFE membrane achieves bacterial retention at the rated pore size while limiting the hydrophobic interactions that draw proteins and handles both aqueous buffers and organic solvents. Polypropylene construction resists chemical degradation from routine sample matrices while routing flow to minimize backpressure in service and preserves sample chemistry across the flow path. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Prefiltration
- Glass fiber prefilter stage sustains flow through particle-laden, hard-to-filter samples
- Two-stage construction pairs a borosilicate glass fiber prefilter with the downstream membrane
- Added glass fiber stage extends usable throughput by delaying membrane clogging
- Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
Membrane Characteristics
- The membrane turns optically clear on contact with water, confirming full wetting
- Chemical compatibility holds steady across the full pH 1 to 14 range
- The membrane's chemical compatibility extends to aggressive organic solvents beyond aqueous solutions
- The fluoropolymer's chemical inertness keeps proteins stable in solution
- Absolute-rated pore structure delivers repeatable particle capture batch to batch
Housing Characteristics
- Medical-grade polypropylene with broad chemical compatibility
- Thermal-bonded construction keeps adhesives out of the fluid path
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Upstream sample clarification keeps your separations clean and reproducible from sample preparation through final injection. Talk to the Tisch Scientific team about consolidating your Pall filtration purchases under one volume-pricing agreement.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 42psi
- Connection Type
- Luer-Lock/ Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 2.8cm²
- Flow Rate
- 120ml
- Holdup Volume
- < 100 µL
- Material
- Hydrophilic PTFE (wwPTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 55°C
- Pack Count
- 1000
- Pore Size (µm)
- 0.2
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 15-20 min
- Wettability
- Hydrophilic
- LC-MS Sample Prep - Minimizes membrane-derived extractables that can suppress ionization or add background peaks in mass spectrometry detection.
- Pharmaceutical API Testing - Filters active ingredient solutions in mixed aqueous and organic solvents for potency assay and impurity profiling.
- Medical Device Extractables - Filters mixed aqueous and organic extraction media from device materials for biocompatibility evaluation.
- Mobile Phase Degassing - Provides a chemically inert barrier that withstands aggressive solvents used in high-sensitivity gradient chromatography.
- Natural Product Isolation - Clarifies botanical and marine extracts in mixed aqueous and organic media ahead of bioassay-guided fractionation.
- Clinical Chemistry Prep - Prepares serum and plasma filtrates in mixed aqueous and organic media for routine clinical analyzer instruments.