Nanosep MF Centrifugal Devices w/ Bio-Inert Membrane - 0.2um, Aqua, 100/Pk

Thumbnail Filmstrip of Nanosep MF Centrifugal Devices w/ Bio-Inert Membrane - 0.2um, Aqua, 100/Pk Images

    Purchase Nanosep MF Centrifugal Devices w/ Bio-Inert Membrane - 0.2um, Aqua, 100/Pk

    Nanosep MF Centrifugal Devices w/ Bio-Inert Membrane - 0.2um, Aqua, 100/Pk
    Pall SKU: ODM02C34

    $326.95
    Ships in 7 weeks
     

    Nanosep Centrifugal Devices w/ Bio-Inert Membrane - 0.2um, Aqua, 100/Pk - ODM02C34

    Pall Corporation engineers proprietary membrane media and ultrasonically welded housing, purpose-built for demanding sample concentration and clarification workflows. Bio-Inert modified nylon spin filters clarify biological samples at a rated pore size. Bio-Inert modification lowers non-specific binding well below unmodified nylon while staying stable across common laboratory solvents and removes particulates at the rated pore size. When trace analysis depends on a clean sample, low-binding microfiltration clarifies it without losing analyte.

    Key Characteristics

    • Low non-specific binding maximizes protein and analyte recovery from dilute samples
    • Naturally hydrophilic surface loads aqueous samples on contact
    • Compatible with chromatographic mobile phases and common laboratory alcohols
    • Clarifies analytical samples to protect downstream columns and detectors
    • Surface modification keeps non-specific binding well below unmodified nylon

    Removing particulates from your buffers and mobile phases extends column life and keeps your baselines steady. Upstream buffer clarification keeps avoidable particulates out of your flow path across routine and validated analytical methods. Call on the Tisch Scientific team to standardize products across your methods with volume pricing and documentation.

    Pore Size (µm)
    0.2
    Sterility
    Nonsterile
    Wettability
    Hydrophilic
    • HPLC Sample Prep - Clarifies analytical samples before chromatography to protect columns from particulate damage and fouling.
    • Biological Sample Prep - Clarifies cell and tissue preparations ahead of routine analytical and chromatographic workflows.
    • Mobile Phase Clarification - Removes particulates from chromatographic mobile phases and prepared solvents ahead of injection.
    • Sample Clarification - Clears particulates from biological samples at a rated pore size while preserving trace-level analytes.
    • Column Protection - Clears particulates from analytical samples to protect downstream columns and detector flow cells reliably.
    • Trace Analyte Cleanup - Clarifies samples with low non-specific binding to preserve analytes present at trace concentrations.