Chat with us, powered by LiveChat

Secure Checkout
PES Syringe Filters, 0.22 um, 25mm, for Ion Chromagraphy, Nonsterile, 100/Pk

Thumbnail Filmstrip of PES Syringe Filters, 0.22 um, 25mm, for Ion Chromagraphy, Nonsterile, 100/Pk Images

    Purchase PES Syringe Filters, 0.22 um, 25mm, for Ion Chromagraphy, Nonsterile, 100/Pk

    PES Syringe Filters, 0.22 um, 25mm, for Ion Chromagraphy, Nonsterile, 100/Pk
    Tisch SKU: SF18320

    $234.99
    Ships in 4 weeks
     

    Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.22 µm, 25 mm, 100/Pk - SF18320

    Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. Low-binding PES achieves sterile-grade retention with high recovery while leaving proteins less surface area to contact and tolerates aliphatic alcohols, glycols, and aqueous buffers. Polyolefin construction sheds virtually no extractable material into the sample and resists degradation from routine sample matrices. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.

    Membrane Characteristics

    • Mechanical strength keeps the matrix intact under vacuum or pressure
    • Chemical breadth spans alcohols, glycols, and aqueous buffers
    • Compatibility spans both nucleic acid and protein-based filtration
    • PFAS extractables test non-detectable under EPA Method 537.1
    • Pore structure integrity holds through autoclave cycles up to 126°C

    Housing Characteristics

    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate
    • Rated operating pressure supports filtration of high-resistance and viscous samples without housing distortion
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Plasticizer-free polyolefin construction keeps the fluid path clean

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request blanket-order pricing and paperwork support for your routine filtration purchases.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    43.51psi
    Burst Pressure (psi)
    87psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    30ml
    Holdup Volume
    100μL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-160μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    No
    Prefilter Material
    /
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
    • Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.