Polyethersulfone (PES) Capsule Filters - SF14953
PES capsule filters combine asymmetric membrane architecture with ultra-low protein adsorption, maximizing throughput while preserving the biological activity of filtered solutions. Designed for laboratory performance, PES membrane chemistry delivers broad pH compatibility from 1 to 14, supporting filtration of buffers, media, and cleaning solutions through a single capsule platform without material degradation. As a result, the outcome is a validated filtration barrier that arrives ready for process integration, supporting the single-use manufacturing strategies adopted by modern pharmaceutical and biotechnology facilities.
Key Polyethersulfone (PES) Membrane Characteristics
- PES capsule filters achieve flow rates that support large-batch processing without the mid-run device changes that disrupt sterile workflows and introduce contamination risk.
- Maximum operating temperature of 80 degrees Celsius supports filtration of warm solutions and accommodates the thermal conditions present in process environments.
- PES membrane construction supports integrity testing by forward flow, bubble point, or pressure decay methods, providing the post-use verification required by pharmaceutical quality systems.
- Ultra-low protein binding characteristics of the PES membrane minimize adsorptive losses, preserving the concentration and biological activity of filtered proteins, antibodies, and growth factors.
- The asymmetric pore structure of PES membranes captures contaminants at the upstream surface while maintaining open downstream channels, extending capsule throughput before reaching differential pressure limits.
Key Capsule Construction Features
- Single-use polypropylene capsule construction eliminates cleaning validation requirements, reducing the regulatory burden and turnaround time associated with reusable stainless steel filter housings.
- Thermally fused polypropylene construction eliminates adhesives, binders, and O-rings from the fluid path, reducing extractable contamination and simplifying material qualification.
- Polypropylene capsule housing provides broad chemical compatibility from pH 1 to 14, resisting the acids, bases, and process chemicals that degrade alternative housing materials.
- Polypropylene capsule housing supports autoclave sterilization at 121 degrees Celsius and withstands gamma irradiation exposure, accommodating both user-sterilized and factory-sterilized device configurations.
Whether your process requires sterilizing-grade retention for a 500-milliliter bench trial or clarification capacity for a 100-liter production batch, the right capsule filter configuration eliminates the compromises between throughput, retention, and operational simplicity. Under these conditions, if your process involves aqueous biologicals, the ultra-low protein binding and broad pH compatibility of PES membrane construction protect your product while sustaining the flow rates your batch schedule requires. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.
Sterilization Guidance
Non-sterile delivery accommodates applications where sterility is not required, while the all-polypropylene construction provides the option for autoclave sterilization when aseptic processing is specified.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 26.1psi
- Compliance Standards
- ISO 9001
- Connection Type
- 1/4 in. MNPT
- Construction
- Polypropylene
- Diameter
- 72mm
- Dimensions
- 72mm x 172mm
- Filling Bell (Yes/ No)
- No
- Filtration Area
- 2100cm²
- Flow Rate
- 9.5 L/min at 0.1 bar
- Holdup Volume
- 89mL
- Inlet Connection
- 1/4 in. MNPT
- Length
- 172mm
- Material
- PES
- Max Batch Volume
- <100L
- Maximum Operating Pressure
- 75.4psi
- Maximum Operating Temperature (°C)
- 80°C
- Outlet Connection
- 1/4 in. MNPT
- Pack Count
- 1
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable at 121°C for 30 mins
- Vent (Yes/ No)
- Yes
- Weight
- 0.49
- Wettability
- Hydrophilic
- Reagent Filtration - Removal of particulates and contaminants from laboratory reagents and process solutions before downstream use.
- Serum Processing - Capsule filtration of animal sera and biological supplements for cell culture and diagnostic reagent applications.
- Buffer Processing - Large-volume filtration of pharmaceutical buffers and process solutions with broad pH compatibility across pH 1-14.
- Water Purification - Membrane-grade filtration of purified water and water-for-injection systems in pharmaceutical manufacturing facilities.
- Biologics Protection - Ultra-low protein binding preserves antibody and growth factor concentrations through the membrane retention step.
- Process Intermediates - In-line capsule filtration of pharmaceutical intermediates with validated retention and low adsorptive losses.