Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.1 µm, 25 mm, 100/Pk - SF18121
Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. PES's open pore layout leaves proteins less surface to contact and tolerates aliphatic alcohols, glycols, and aqueous buffers. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use and holds its seal true run after run. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Prefiltration
- High dirt-holding capacity sustains flow through turbid, viscous, particle-laden samples
- Two-stage construction pairs an upstream polypropylene depth prefilter with the final membrane
- Polypropylene prefilter resists acids, bases, and common organic solvents
- Polypropylene prefilter adds no glass fibers to the filtrate
Membrane Characteristics
- Sulfone backbone's hydrolytic stability tolerates repeated autoclave steam sterilization cycles
- Aromatic sulfone backbone underlies stability across the full pH range
- PFAS extractables test non-detectable under EPA Method 537.1
- Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
- Non-ionic surface avoids charge-driven protein binding of positively and negatively charged membrane types
Housing Characteristics
- Standardized luer connection geometry provides secure engagement with standard syringe tips
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Medical-grade polypropylene with broad chemical compatibility
An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Upstream buffer clarification keeps your run from stalling on particulates that slipped through while keeping the filtrate analytically clean. Request details on payment terms or standing-order arrangements for your routine filtration purchases.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 26.11psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/Luer Slip
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 16ml
- Holdup Volume
- 100μL
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 100-160μm
- Pack Count
- 100
- Pore Size (µm)
- 0.1
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Nonsterile
- Sterilization
- Autoclave 121°C for 30min/ gamma 25kGy
- Volume Throughput (ml)
- 50ml
- Weight
- 0.52
- Wettability
- Hydrophilic
- Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
- Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
- Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
- Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.
- Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
- Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.