Chat with us, powered by LiveChat

Secure Checkout
PES Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PES Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PES Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PES Syringe Filters, 0.22 um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF14499

    $121.99
    Only 20 in stock. Order now!
     

    Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.22 µm, 25 mm, 100/Pk - SF14499

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Sterilizing-grade syringe filters deliver sterile-grade retention as a single-use format, eliminating the autoclaving and cleaning cycle a reusable sterile filtration setup would require. PES pairs fast flow with reduced protein and antibody adsorption while handling strong bases across a broad aqueous range and admits aqueous reagents on contact, skipping any surfactant rinse. Polypropylene construction maintains a low-dead-volume internal flow path and holds its seal true run after run. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • PFAS extractables test non-detectable under EPA Method 537.1
    • Non-hydrogen-bonding surface avoids the polar adsorption nylon's amide backbone causes
    • Antibody and protein samples pass through PES with minimal adsorptive loss
    • Absolute pore size rating holds consistent across every lot
    • Mechanical strength keeps the matrix intact under vacuum or pressure

    Housing Characteristics

    • Thermal-bonded construction keeps adhesives out of the fluid path
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Request volume pricing and stock availability on your filtration product selection from the Tisch Scientific team.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    43.51psi
    Burst Pressure (psi)
    87psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    24ml
    Holdup Volume
    100μL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-160μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.
    • PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.
    • Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.