Chat with us, powered by LiveChat

Secure Checkout
PES Syringe Filters, 0.22 um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PES Syringe Filters, 0.22 um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PES Syringe Filters, 0.22 um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PES Syringe Filters, 0.22 um, 17mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF15606

    $110.95
    4 in stock. Additional units ship in 4 weeks.
     

    Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.22 µm, 17 mm, 100/Pk - SF15606

    Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. PES handles strong bases and oils across a broad aqueous range while needing a surface treatment before its polysulfone base wets and keeps that modified surface active throughout use. The PP housing stays inert across common laboratory solvents and buffers in routine use and holds its seal true run after run. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Compatibility spans both nucleic acid and protein-based filtration
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
    • Finest available pore ratings achieve aseptic-grade filtration performance
    • Antibody and protein samples pass through PES with minimal adsorptive loss
    • Absolute pore size rating holds consistent across every lot

    Housing Characteristics

    • Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
    • Stable across the full aqueous pH range in routine sample work
    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Optimized internal geometry minimizes backpressure in service

    Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data so column life and baseline stability stay predictable. Request details on payment terms or standing-order arrangements for your routine filtration purchases.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    43.51psi
    Burst Pressure (psi)
    87psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    17mm
    Filtration Area
    1.65cm²
    Flow Rate
    13ml
    Holdup Volume
    20μL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-160μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    GF
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    20ml
    Weight
    0.33
    Wettability
    Hydrophilic
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
    • Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
    • Biological Assays - Protects sensitive enzymatic and antibody-based assays from particulate interference without adsorbing critical reagents.
    • Media Preparation - Facilitates rapid sterilization of tissue culture additives, lowering contamination risk during sensitive laboratory work.
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • Cell Culture - Reduces the risk of mycoplasma contamination in growth media, supporting healthier cell lines and more reliable experimental outcomes.