PES Syringe Filters, 0.05um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of PES Syringe Filters, 0.05um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase PES Syringe Filters, 0.05um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    PES Syringe Filters, 0.05um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF16008

    $158.95
    Ships in 4 weeks
     

    Tisch Scientific Polyethersulfone (PES) Syringe Filters, 0.05 µm, 13 mm, 100/Pk - SF16008

    Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. The PES matrix tolerates aliphatic alcohols, glycols, and aqueous buffers while admitting aqueous reagents on contact, skipping any surfactant rinse and gives protein molecules fewer surface sites to adsorb. The polypropylene housing holds its seal true run after run while shedding virtually no extractable material into the sample and routes flow to minimize backpressure in service. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Absolute pore size rating holds consistent across every lot
    • Non-hydrogen-bonding surface avoids the polar adsorption nylon's amide backbone causes
    • Inherent hydrophilicity allows instant aqueous wetting with no pre-wetting step
    • Compatibility spans both nucleic acid and protein-based filtration
    • Ionic extractables from the membrane stay very low

    Housing Characteristics

    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request available pack sizes and lead times across this filtration line's membrane options from the Tisch Scientific team.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    v
    Bubble Point (psi)
    37.71psi
    Burst Pressure (psi)
    87psi
    Connection Type
    Luer-Lok/Luer Slip
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    3ml
    Holdup Volume
    10μL
    Material
    Polyethersulfone (PES)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    100-160μm
    Pack Count
    100
    Pore Size (µm)
    0.05
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    10ml
    Weight
    0.19
    Wettability
    Hydrophilic
    • PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.
    • Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
    • Urine Drug Screening - Clarifies protein-poor urine samples for dilute-and-shoot LC-MS/MS toxicology testing without adsorbing target drug analytes.
    • Pesticide Residue Testing - PES membranes improve polar pesticide recovery in food-safety LC-MS/MS testing versus hydrogen-bonding nylon.
    • Organic Carbon Testing - Clarifies water samples ahead of DOC and UV254 analysis while keeping organic carbon adsorption to the membrane minimal.
    • Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.