Polyethersulfone (PES) Syringe Filters - SF18254
Featuring hydrophilic polyethersulfone membrane technology optimized for rapid clarification of small volume samples in sterile environments. A 0.45µm pore configuration, combined with glass fiber prefiltration, delivers exceptional flow rates while removing particulates from sensitive biological and pharmaceutical preparations. Tisch Scientific engineers precision 17mm diameter construction with minimal holdup volume, maximizing sample recovery in microscale and analytical applications.
Key Polyethersulfone (PES) Membrane Characteristics
- Naturally hydrophilic membrane provides instant wetting without surfactants or pre-conditioning
- Superior chemical resistance withstands aggressive organic solvents and pH ranges from 1-14
- Low protein binding characteristics preserve analyte concentration and biological activity
- 0.45µm pore size delivers reliable clarification and suspended particulate removal
- Sterile packaging ensures contamination-free filtration for sensitive applications
Key Construction Characteristics
- Glass fiber prefilter captures larger particles, extending primary membrane service life
- Dual Luer-Lok/Luer Slip connections accommodate all standard syringe configurations
- Compact 17mm diameter design optimizes performance for small volume filtration
- 20µl holdup volume ensures maximum sample recovery in precious or limited samples
SF18254 syringe filters achieve remarkable 26.5ml/min flow rates through a compact 1.65cm² filtration area, accelerating your sample processing while maintaining consistent 31.91psi bubble point integrity. Glass fiber prefiltration technology protects the primary membrane from fouling, delivering reliable performance throughout the 20ml throughput capacity for your critical small-volume applications. Individually packaged sterile units eliminate contamination risks, ensuring reproducible results when processing your most sensitive samples requiring both clarification and sterility assurance.
For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 31.91psi
- Burst Pressure (psi)
- 87psi
- Connection Type
- Luer-Lok/ Luer Slip
- Diameter
- 17mm
- Filtration Area
- 1.65cm²
- Flow Rate
- 26.5ml
- Holdup Volume
- 20μL
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 100-160μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- GF
- Sterility
- Sterile
- Volume Throughput (ml)
- 20ml
- Weight
- 0.70
- Wetability
- Hydrophilic
- Sample Clarification Applications - Removes particles larger than 0.45µm from cell culture supernatants and biological fluids for analysis
- HPLC Sample Preparation - Protects analytical columns from particulate damage and backpressure buildup in chromatography systems
- Protein Solution Processing - Gently clarifies antibodies and enzymes while preserving full biological activity and potency
- Cell Culture Media Clarification - Removes particulates from serum and growth factor solutions while maintaining essential nutrients
- Environmental Sample Processing - Removes particulates from water and soil extracts before instrumental analysis and testing
- Pharmaceutical Quality Control - Prepares samples for dissolution testing and content uniformity analysis in regulated laboratories