Chat with us, powered by LiveChat

Secure Checkout
Polypropylene Syringe Filters, 0.22 um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of Polypropylene Syringe Filters, 0.22 um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase Polypropylene Syringe Filters, 0.22 um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    Polypropylene Syringe Filters, 0.22 um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk
    Tisch SKU: SF14692

    $120.95
    Ships in 4 weeks
     

    Tisch Scientific Polypropylene (PP) Syringe Filters, 0.22 µm, 13 mm, 100/Pk - SF14692

    Tisch Scientific makes the ordering process straightforward, turning around requests for pricing and product information fast. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. Polypropylene keeps binding low while capturing particulates through its depth while pairing hydrophobic behavior with chemical resistance and holds up to aggressive process chemistries. Polypropylene construction maintains a low-dead-volume internal flow path and holds its seal true run after run. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Anion leaching stays very low from the matrix
    • Nonpolar surface chemistry favors organic solvents and other non-aqueous liquids
    • Dense polypropylene fiber network intercepts fine particles through the full medium depth
    • PP/PE depth medium tolerates progressive particle accumulation as dirt-holding capacity fills
    • Extractable levels remain very low across the depth matrix

    Housing Characteristics

    • Stable across the full aqueous pH range in routine sample work
    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Polypropylene housing tolerates ethylene oxide gas sterilization cycles without softening or dimensional distortion

    A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.

    Sterilization Guidance

    Factory sterilization supports immediate use in workflows where sterility assurance matters.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    14.50psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    5.5ml
    Holdup Volume
    20μL
    Material
    Polypropylene (PP)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    140-260μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    No
    Sterility
    Sterile
    Volume Throughput (ml)
    10ml
    Weight
    0.40
    Wettability
    Hydrophobic
    • Trace Metal Analysis Prep - Introduces minimal metal ion background into the filtrate, supporting sample prep ahead of ICP-OES or ICP-MS analysis.
    • Lubricant Sample Prep - Filters petroleum-based and synthetic lubricant samples in aliphatic solvent media for ISO cleanliness and wear analysis.
    • Diesel and Biodiesel Analysis - Filters fuel samples in alcohol and aliphatic solvent matrices for ASTM method compositional and purity testing.
    • Acetonitrile Sample Prep - Handles neat and diluted acetonitrile mobile phases and extracts for pharmaceutical and environmental workflows.
    • Sample Cleanup - Clarifies organic solvents during synthesis and purification steps, helping remove reaction byproducts and debris before analysis.
    • Mineral Acid Compatibility - Withstands concentrated hydrochloric acid and strong caustic bases in aqueous inorganic extraction workflows.