Tisch Scientific Polypropylene (PP) Syringe Filters, 0.45 µm, 25 mm, 100/Pk - SF14691
Tisch Scientific vets its filtration partners carefully, favoring those with a consistent record of dependable output. A syringe filter's small hold-up volume limits sample loss, a meaningful difference when working with a limited or precious sample. Polypropylene resists a broad range of organic solvents, acids, and bases in service and combines water-repelling character with wide chemical durability. Low-extractable polypropylene keeps sample purity intact through the filtration pass while maintaining a low-dead-volume internal flow path and holds its seal true run after run. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Membrane Characteristics
- Dense polypropylene fiber network intercepts fine particles through the full medium depth
- Compatible with dilute acids, ketones, and aliphatic esters at room temperature
- Solvent-stable polypropylene handles aliphatic hydrocarbons and common process oils
- Sustains throughput on particulate-laden solvent samples
- Flexible polypropylene fiber matrix adapts to modest pressure cycles without fracture
Housing Characteristics
- The seal formed against the membrane blocks bypass at rated operating pressure
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Stable across the full aqueous pH range in routine sample work
- Impact-tolerant polypropylene body withstands routine bench handling without damage
A filter that softens or swells in your solvent fails you mid-run, batch after batch. Solvent-stream filtration handles the solvents and reagents your methods rely on across the organic solvents and harsh reagents your methods use. Start a live chat with the Tisch Scientific team for real-time updates on product availability, lead time, or your order status.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 7.40psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 35ml
- Holdup Volume
- 100μL
- Incompatibility
- Esters, hexane, toluene, benzene, dichloromenthan
- Material
- Polypropylene (PP)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 140-260μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclave 121°C for 30min/ gamma 25kGy
- Volume Throughput (ml)
- 50ml
- Weight
- 0.52
- Wettability
- Hydrophobic
- Flavor and Fragrance Prep - Handles alcohol-based flavor and fragrance concentrate preparations before GC-MS aroma compound profiling.
- Rubber Compound Testing - Filters cyclohexane and alcohol rubber extract solutions for antioxidant and additive content analysis by chromatography.
- Mineral Acid Compatibility - Withstands concentrated hydrochloric acid and strong caustic bases in aqueous inorganic extraction workflows.
- Polymer Solution Prep - Handles THF and alcohol polymer solutions with high loads for GPC and SEC column protection and sample clarification.
- Diesel and Biodiesel Analysis - Filters fuel samples in alcohol and aliphatic solvent matrices for ASTM method compositional and purity testing.
- DMSO Solution Handling - Filters dimethyl sulfoxide preparations and drug formulations without the membrane degradation of less resistant polymers.