Tisch Scientific Polypropylene (PP) Syringe Filters, 0.45 µm, 13 mm, 100/Pk - SF14705
Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. Polypropylene resists a broad range of organic solvents, acids, and bases in service and keeps water out during solvent and gas-purge steps. The PP housing sustains efficient flow on viscous samples while leaving no seam for sample to bypass the membrane and stands firm against aqueous acids, bases, and alcohols during regular handling. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.
Membrane Characteristics
- Compatible with dilute acids, ketones, and aliphatic esters at room temperature
- Metal-ion leaching resistance holds during acid-digested sample filtration
- Saturated hydrocarbon backbone resists the hydrolytic degradation common in ester-linked filter media
- Dense polypropylene fiber network intercepts fine particles through the full medium depth
- Anion leaching stays very low from the matrix
Housing Characteristics
- Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
- Translucent housing wall allows visual confirmation of sample flow during filtration
- Medical-grade polypropylene with broad chemical compatibility
- Impact-tolerant polypropylene body withstands routine bench handling without damage
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Solvent-stream filtration handles the solvents and reagents your methods rely on so your filter holds its integrity through the run. Request details on payment terms or standing-order arrangements for your routine filtration purchases.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 7.40psi
- Burst Pressure (psi)
- 87psi.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 13mm
- Filtration Area
- 1.09cm²
- Flow Rate
- 11ml
- Holdup Volume
- 20μL
- Incompatibility
- Esters, hexane, toluene, benzene, dichloromenthan
- Material
- Polypropylene (PP)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 140-260μm
- Pack Count
- 100
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclave 121°C for 30min/ gamma 25kGy
- Volume Throughput (ml)
- 10ml
- Weight
- 0.19
- Wettability
- Hydrophobic
- Mining Acid Leachate Analysis - Processes dilute sulfuric acid mine drainage and leachate samples for dissolved metal and ion speciation analysis.
- General Lab Use - Supports the clarification of diverse solvent-based and process liquid streams, providing a reliable and cost-effective solution.
- Bulk Solvent Filtration - Handles pressure fluctuations during syringe filtration of bulk solvents and lab reagents reliably.
- Hexane Extract Filtration - Handles non-polar hexane extracts from food, environmental, and pharmaceutical matrices without swelling or extractables.
- Sample Cleanup - Clarifies organic solvents during synthesis and purification steps, helping remove reaction byproducts and debris before analysis.
- Acetonitrile Sample Prep - Handles neat and diluted acetonitrile mobile phases and extracts for pharmaceutical and environmental workflows.