Chat with us, powered by LiveChat
Secure Checkout
Polypropylene Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

Thumbnail Filmstrip of Polypropylene Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk Images

    Purchase Polypropylene Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk

    Tisch
    Polypropylene Syringe Filters, 0.45um, 13mm, Luer-Lok/Luer Slip, Sterile, 100/Pk SKU: SF18218

    $117.65
    Ships in 4 weeks
     

    Polypropylene (PP) Syringe Filters - SF18218

    Small-volume pharmaceutical and biological workflows face persistent challenges balancing rapid particulate removal with maximum sample recovery while maintaining sterile processing conditions throughout analytical preparation. Excessive holdup volumes and slow flow rates compromise precious sample yields, creating bottlenecks in quality control testing and research applications. Gamma-sterilized 0.45µm polypropylene membrane technology resolves these limitations through compact 13mm platform design that delivers efficient clarification with exceptional sample preservation. Technical specifications include validated 7.40psi bubble point ensuring consistent particulate retention, 1.09cm² filtration area, and minimal 20µL holdup volume supporting 11ml flow rate with 10ml throughput capacity for economical small-volume processing.

    Key Polypropylene Membrane Characteristics

    • Clarification-focused 0.45µm architecture removes particulates from biological and pharmaceutical samples while maintaining rapid processing rates for small-volume workflows
    • Gamma-sterilized, ready-to-use design provides contamination control throughout sample handling without bacterial retention specifications for pharmaceutical applications
    • Hydrophobic membrane structure requires pre-wetting with a compatible organic solvent before aqueous filtration, establishing flow pathways through the polypropylene matrix
    • Economical construction supports cost-effective routine clarification operations while maintaining consistent performance across compatible chemical environments
    • Selective chemical resistance maintains compatibility with acids, bases, and aqueous solutions after proper pre-wetting, while being incompatible with esters

    Key Construction Characteristics

    • Minimal 20µL holdup volume maximizes recovery of valuable samples during 1-10ml processing, where every microliter directly impacts analytical precision and project economics
    • Compact 13mm platform provides space-efficient clarification for small-volume applications with 11ml flow rate performance at 87psi maximum operating pressure
    • Universal Luer-Lok/Luer Slip interface eliminates adapter requirements, enabling rapid connections with standard laboratory syringes for streamlined workflow integration
    • Moderate-temperature polypropylene housing operates reliably up to 60°C maximum temperature, accommodating ambient and slightly elevated processing conditions

    Built to support your small-volume clarification requirements where sample recovery cannot be compromised, gamma-sterilized construction delivers dependable performance. Validated 7.40psi bubble point provides operational confidence throughout pharmaceutical workflows. Minimal holdup design combined with compact platform geometry ensures your laboratory operations maintain both efficiency and economy across diverse applications requiring sterile particulate removal.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    7.40psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene (PP)
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    11ml
    Holdup Volume
    20μL
    Material
    Polypropylene (PP)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    140-260μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    No
    Sterility
    Sterile
    Volume Throughput (ml)
    10ml
    Weight
    0.40
    Wetability
    Hydrophobic
    • Small-Volume HPLC Prep - Removes particulates from analytical samples, while gamma-sterilized construction maintains integrity throughout processing
    • Biological Sample Clarification - Filters proteins and sera to eliminate cellular debris before downstream instrumental analysis or storage
    • Pharmaceutical QC Testing - Processes small-volume drug formulations requiring sterile particulate removal with maximum sample recovery
    • Organic Solvent Processing - Hydrophobic compatibility filters, chromatography phases, and non-aqueous reagents following appropriate pre-wetting
    • Protein Sample Preparation - Clarifies enzyme solutions and biological extracts with exceptional recovery through a minimal holdup design
    • Routine Quality Control - Guards analytical instruments from particulate contamination in small-volume laboratory testing workflows