Tisch Scientific Polypropylene (PP) Syringe Filters, 10 µm, 25 mm, 100/Pk - SF18270
Tisch Scientific vets its filtration partners carefully, favoring those with a consistent record of dependable output. A syringe filter's small hold-up volume limits sample loss, a meaningful difference when working with a limited or precious sample. Low-binding polypropylene sustains throughput as a depth medium and stays well suited to solvent-rich, non-aqueous specimens. Polypropylene construction maintains a low-dead-volume internal flow path while keeping sample purity intact through the filtration pass and stands firm against aqueous acids, bases, and alcohols during regular handling. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- Extractable levels remain very low across the depth matrix
- Broad solvent tolerance includes glycols, aliphatic alcohols, and dilute salt solutions
- Saturated hydrocarbon backbone resists the hydrolytic degradation common in ester-linked filter media
- Trace-metal contribution from the polypropylene matrix remains negligible in analytical use
- Solvent-stable polypropylene handles aliphatic hydrocarbons and common process oils
Housing Characteristics
- Thermal-bonded construction keeps adhesives out of the fluid path
- Polypropylene housing withstands rated backpressure from dense sample matrices without deformation
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
Particulates left in your organic solvents and reagents carry downstream into the step that depends on a clean feed. Reliable solvent prefiltration keeps a stray particulate from carrying into your downstream work so your downstream method starts with a clean sample. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- Polypropylene (PP)
- Diameter
- 25mm
- Filtration Area
- 4.08cm²
- Flow Rate
- 250ml
- Holdup Volume
- 100μL
- Material
- Polypropylene (PP)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 140-260μm
- Pack Count
- 100
- Pore Size (µm)
- 10.0
- Prefilter (Yes/No)
- No
- Sterility
- Sterile
- Volume Throughput (ml)
- 50ml
- Weight
- 0.88
- Wettability
- Hydrophobic
- Prefiltration Support - Protects downstream membrane filters by capturing gross contaminants, extending the purification system life.
- Biopharma Prefiltration - Removes large particulates from fermentation and upstream bioprocess streams ahead of membrane filtration steps.
- Hormone and Steroid Testing - Handles alcohol and acetonitrile steroid extraction matrices for HPLC-MS confirmation in pharmaceutical QC labs.
- Textile Dye Wastewater - Processes aqueous and alcohol-containing dye effluents for absorbance monitoring and color removal tracking.
- Mineral Acid Compatibility - Withstands concentrated hydrochloric acid and strong caustic bases in aqueous inorganic extraction workflows.
- Polymer Solution Prep - Handles THF and alcohol polymer solutions with high loads for GPC and SEC column protection and sample clarification.